bg

Plug in high quality electric cable termination for 110 KV

We are one of the leading factory in North China manufacturing wires and cables with over 20 years experiences. Our cables division has a very wide range of products, our competitive products are LV and HV XLPE Insulated Power Cables, PVC Insulated Power Cables, Low Smoke, Zero (Low)-Halogen Flame Retardant Cables, Coaxial Cables, Fireproof Cables, Aluminum Alloy Cables, Cabtyre Cables, Overhead Cables, Control Cables, Silicone Rubber Cables, Ribbon Cables, High and Low Temperature Corrosion Resistant Cables, Mineral Insulated Cables, Other special cables according to customer requirements and Cable Accessories.

  • Ruiyang
  • Shenyang
  • 15 days
  • 100 per month
  • Information
  • Download


          型号Model

YJZGG

额定电压 Rated voltage

66kV

110kV

220kV

最髙工作电压 Maximum working voltage

72.5kV

126kV

252kV

雷电冲击电压 Lightning impulse voltage

450kV

550kV

1050kV

长度(带延长杆) Length (with extension rod)

310mm (583mm)

470mm(757mm)

620(960)mm

计算重量(带延长杆) Calculated weight(with extension rod)

28kg

38kg(42kg)

150(190)kg

SF6工作压力SF6 working pressure

0.2 ~ 0.6MPa

0.2 ~ 0.6MPa

<=0.85MPa

导体规格     Conductor specifications

1600mm2

1600mm2

2500mm2

绝缘外径  scope  Insulation outer diameter

<=82mm

<=84mm

114mm

执行标准 Execution standard

IEC60859

GB/T11017

GB/T18890

1. Assembly  

The whole termination is composed of two parts: epoxy bushing and plug-in splice.

2. Premold

The equipment or cable lines can be repaired or maintained without breaking the seal between Pre-insxalled epoxy bushing and the equipment.

Indoor Termination

3. Cone

The silicone rubber stress cone provides the electric stress control.Prefabricated silicone rubber stress cone is subject to 100% delivery inspection

4. Springs

The connectors with multipoint contact springs are used to provide good contact with conductors.The metal spring pressure device can ensure that the stress cone is always closely attached to the inner wall of the matched epoxy bushing and the interfacial pressure is ensured.

Outdoor Termination

5.Install

The cable fixing and sealing device of the Termination will be connected with the outer sheath of the cable to play the role of fixing and mechanical protection, which can provide a separate grounding.No special tools or brazing are required for termination installation.The bottom flange and the termination can be grounded separately.Dry type interface, no oil

6.Replace

When it is necessary to replace the old oil-filled Termination installed in the transformer or oil-filled insulated switchgear, the extension rod and fixing ring can be selected to match the Termination outgoing line position.

electric cable termination

7.Specification

Size:    IEC62271 -209GB/T22381IEC60859

Test:   GB/T 18890GB/T11017